A delta connected load with each Z = 8 30degree ohms is supplied from a balanced three phase wye connected generator through lines having series impedance of 0.25 30degree ohms. The line-to-line voltage measured at the load is 208 volts (for the angle, please use load Vab as the reference, such that Vab = 208 0degree volts). Calculate the three load phase currents (magnitude and angle). Calculate the magnitude of the line-to-line voltage at the generator. Calculate the power factor at the generator (be sure to indicate leading or lagging).

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:10
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
A delta connected load with each Z = 8 30degree ohms is supplied from a balanced three phase wye con...
Questions
question
History, 03.12.2020 14:00
question
World Languages, 03.12.2020 14:00
question
English, 03.12.2020 14:00
question
Mathematics, 03.12.2020 14:00
Questions on the website: 13722367