subject
Engineering, 11.02.2020 04:23 Beth6013

CNT Books has expanded considerably since you first got the network up and running three years ago. It now occupies an entire floor in the building, and its LAN has grown to include several servers and more than 60 workstations. CNT Books has recently purchased another book company and needs more space and computers. Expansion plans include leasing another floor four stories up in the same building and adding 35 workstations and at least one more server immediately, with additional equipment purchases expected. What type of network is called for – LAN, WAN, MAN, or internetwork? What additional devices might be needed to ensure efficient network communications?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 18:10
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
question
Engineering, 04.07.2019 18:10
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
CNT Books has expanded considerably since you first got the network up and running three years ago....
Questions
question
Social Studies, 23.04.2021 20:50
question
Mathematics, 23.04.2021 20:50
question
Mathematics, 23.04.2021 20:50
question
Physics, 23.04.2021 20:50
question
Mathematics, 23.04.2021 20:50
Questions on the website: 13722362