subject
Engineering, 17.12.2019 21:31 alwayspouty6438

Anew machine needs to be added into a maintenance department among five existing machines, which are currently located in coordinates: p1 (1, 1), p2 (6, 2), p3 (2, 8), p4 (3, 6) and p5 (8, 4). the cost per unit distance traveled between the new machine and each existing machine is the same. the number of trips per day between the new machine and the existing machines 1, 2, 3, 4 and 5 are 10, 20, 25, 20 and 25, respectively. (50 pts)

1) identify the best location for the new machine. your submission needs to include:

a) the m-file
b) the calculated minimum cost and the location coordinates

2) alternatives are required for the best location of 1). thus, an iso-cost contour map is needed to identify possible alternative locations. calculate the iso-cost contour map of this question. your submission needs to include:

a) the m-file.
b) a large-area, coarse map with labels. mark the identified best location, p1, p2, p3, p4, and p5 on this contour map.
c) a small-area (zoom in on the center), fine map without labels.

3) compare 1) and 2)’s results and check if the coordinate location in 1) matches the center of the contour lines in 2)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Explain the difference laminar and turbulent flow. explain it with the shear stress and the velocity profiles.
Answers: 1
question
Engineering, 04.07.2019 08:10
Which of the following is an easy way to remember the modified “x” tire rotation? a. nondrive wheels straight, cross the drive wheels b. drive wheels straight, cross the nondrive wheels c. drive wheels crossed, nondrive wheels straight d. drive wheels crossed, nondrive wheels crossed
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
You know the right answer?
Anew machine needs to be added into a maintenance department among five existing machines, which are...
Questions
question
Mathematics, 09.03.2021 17:40
question
Mathematics, 09.03.2021 17:40
question
Spanish, 09.03.2021 17:40
question
Mathematics, 09.03.2021 17:40
question
Mathematics, 09.03.2021 17:40
question
Law, 09.03.2021 17:40
Questions on the website: 13722367