subject
Engineering, 13.12.2019 21:31 dumngirl2504

At krispy kreme the process for sugar coating donuts by the sugar-waterfall donut coater involves a flow of uncoated donuts into the donut coater and the output consists of the sugar coated donuts. the coater also receives an inflow of sugar suspension which coats the donuts. the unused sugar suspension is recycled to a mixer which is positioned ahead of the donut coater. an input pipe goes into the mixer and supplies sugar suspension which replaces the sugar that coats the donuts and leaves the system. the flow rate of donuts into the coater is 1200 donuts/hr and each uncoated donut weights approximately 110 g. 12 kg/h of sucrose suspension leaves the system when the donuts are coated but most of the sugar is recycled through the mixer. the mixer output stream of sucrose suspension has a mass flow rate of 126 kg/hr.

a. create a process flow diagram of the donut coater system described above, labeling the input mass flow of sugar suspension as m1 and the output flow of coated donuts as m2, and the recycle flow as m3. label the output mass fractions of donuts and sugar suspension using as few variables as possible. (5 points)
b. what is the mass flow of coated donuts? (5 points)
c. what is the mass flow of input sugar suspension (5 points)
d. what is the mass flow of the recycled sugar suspension (5 points)
e. what is the mass fraction of sugar suspension on the coated donuts? (5 points)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 03.07.2019 14:10
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
You know the right answer?
At krispy kreme the process for sugar coating donuts by the sugar-waterfall donut coater involves a...
Questions
question
Mathematics, 03.09.2020 19:01
Questions on the website: 13722367