Consider a solar panel system composed of 100 w modules (i. e., panels) that is coupled with a lead acid battery storage system to be used for a small business. you only plan to store electricity overnight. assume that the panels produce electrical energy 8 hours each day and that the electrical energy is used steadily throughout the day. size the system so that you can provide 48 kwh per day. the capacity factor of the solar panels is 15%. the voltage controller efficiency is 90%. the round trip efficiency is 78%. the depth of discharge is 80%. during the day when power is available from the panels it is provided directly to the house and is not stored in the batteries.

the cell efficiency is 17%. the installed cost of the system is $4.00/w including the pv panels, battery storage, inverters, and modifications to the house. the system has a solar access factor of 95%, a cleanliness factor of 98%, a temperature derate factor of 0.88, wiring and mismatch loss reduction factor 95%, an inverter efficiency of 90%, and a storage efficiency (i. e., round trip efficiency) of 95% based on input energy. assume that all power delivered by the system is provided through the batteries. solar insolation in the region average averages 250 w/m2 year round. the system may be purchased with a 20 year payback period at an interest rate of 6%. o& m costs are $0.01/kwh. the household has an annual electricity usage of 11,000 kwh. each panel requires 0.72 m2 of roof area.

how much power do the panels need to provide directly to the house (kwh/day)?

how much power do the panels need to provide to the batteries (kwh/day)?

what is the needed rated capacity of the solar panels (kw)?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:20
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
You know the right answer?
Consider a solar panel system composed of 100 w modules (i. e., panels) that is coupled with a lead...
Questions
question
English, 03.02.2020 15:54
Questions on the website: 13722360