subject
Engineering, 10.12.2019 21:31 jamesk5671

In our discussion of tcp congestion control we implicitly assumed that the tcp sender always had data to send. consider now the case that the tcp sender sends a large amount of data and then goes idle (since it has no more data to send) at t1 . tcp remains idle for a relatively long period of time and then wants to send more data at t2. what are the advantages and disadvantages of having tcp use the cwnd and ssthresh values from t1 when starting to send data at t2 ? what alternative would you recommend? why?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i.d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
question
Engineering, 04.07.2019 19:20
Air enters a horizontal, constant-diameter heating duct operating at steady state at 290 k, 1 bar, with a volumetric flow rate of 0.25 m°/s, and exits at 325 k, 0.95 bar. the flow area is 0.04 m2. assuming the ideal gas model with k = 1.4 for the air, determine (a) the velocity at the inlet and exit, each in m/s, and (c) the rate of heat transfer, in kw flow rate, in kg/s, (b) the mass kg 0.3
Answers: 2
You know the right answer?
In our discussion of tcp congestion control we implicitly assumed that the tcp sender always had dat...
Questions
question
Mathematics, 15.09.2021 05:10
question
Mathematics, 15.09.2021 05:10
question
Mathematics, 15.09.2021 05:10
question
Mathematics, 15.09.2021 05:10
Questions on the website: 13722363