Abuilding with the characteristics listed is located below where the annual heating season lasts 21 weeks. the inside design temperature is 70°f . the average outside air temperature is 30°f. the gas furnace has an efficiency of 75% . fuel costs $0.25 per therm. the building is occupied only from 8 a. m. until 6 p. m., monday through friday. in the past, the building was maintained 70°f at all times and ventilated with one air change per hour (based on inside conditions). the thermostat is now being set back 12°f and the ventilation reduced 50% during the unoccupied times. infiltration through cracks and humidity changes are disregarded . what is the annual savings? data;

internal volume: 801,000 ft3
wall area: 11,040 ft2
wall overall heat transfer coefficient: 0.15 btu/ ft2 -hr-°f
window area: 2760 ft2
window overall heat transfer coefficient: 1.13 btu/ft2 -hr-°f
roof area: 26,700 ft2
roof overall heat transfer coefficient: 0.05 btu/ft2 -hr-°f
slab on grade: 690 lineal ft of exposed slab edge
slab edge coefficient: 1.5 btu/ft-hr-°f

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
Steel is coated with a thin layer of ceramic to protect against corrosion. what do you expect to happen to the coating when the temperature of the steel is increased significantly? explain.