subject
Engineering, 28.11.2019 03:31 babydoll1981

The article "some parameters of the population biology of spotted flounder (ciutharus linguatula linnaeus, 1758) in edremit bay (north aegean sea)" (d. turker, b. bayhan, etal., turkish journal of veterinary and animal science, 2005: 1013-1018) reports that a sample of 482 female spotted flounder had an average weight of 20.95 g with a standard deviation of 14.5 g, and a sample of 614 male spotted flounder had an average weight of 22.79 g with a standard deviation of 15.6 g. can you conclude that the mearn weight of male spotted flounder is greater than that of females?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
How much power could a wind turbine produce if it had the following specifications? cp = 0.45 -d=1.2kg/m3 d=50m v 5m/s
Answers: 2
question
Engineering, 04.07.2019 19:10
Plan an experiment to measure the surface tension of a liquid similar to water. if necessary, review the ncfmf video surface tension for ideas. which method would be most suitable for use in an undergraduate laboratory? what experimental precision could be expected?
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 06.07.2019 03:30
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2
You know the right answer?
The article "some parameters of the population biology of spotted flounder (ciutharus linguatula lin...
Questions
question
Mathematics, 06.07.2019 10:10
question
World Languages, 06.07.2019 10:10
Questions on the website: 13722360