subject
Engineering, 26.11.2019 06:31 emalvidrez5205

Astudent simultaneously prepared two titration mixtures, consisting of diluted bleaching, ki solution, and hcl solution. the student found that the data from the two titrations yielded significantly different percents naocl. explain which determination would give the higher percent naocl. explain what affect the following procedural errors would have on the calculated percent naocl of your bleach solution: a student failed to allow the volumetric pipet to drain completely when transferring the diluted bleaching solution to the flask. a student began the titration with an air bubble in the buret tip. the bubble came out after 5 ml of na2s2o3 solution was released.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Which of the following refers to refers to how well the control system responds to sudden changes in the system. a)-transient regulation b)- distributed regulation c)-constant regulation d)-steady-state regulation
Answers: 1
You know the right answer?
Astudent simultaneously prepared two titration mixtures, consisting of diluted bleaching, ki solutio...
Questions
question
Mathematics, 23.04.2020 20:39
question
Biology, 23.04.2020 20:39
Questions on the website: 13722367