subject
Engineering, 22.11.2019 03:31 felicityhanson1252

Consider proportional-only control of the stirred-tank heater control system in fig. e11.13. the temperature transmitter has a span of 50 ∘f and a zero of 55 ∘f. the nominal design conditions are t = 80 ∘f and ti = 65 ∘f. the controller has a gain of 5, while the gains for the control valve and current-to-pressure transducer are kv = 1.2 (dimensionless) and kip = 0.75 psi/ma, respectively. the time constant for the tank is τ = 5 min. the control valve and transmitter dynamics are negligible. after the set point is changed from 80 to 85 ∘f, the tank temperature eventually reaches a new steady-state value of 84.14 ∘f, which was measured with a highly accurate thermometer. (a) what is the offset? (b) what is the process gain k2? (c) what is the pressure signal pt to the control valve at the final steady state

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 19:10
Aplate of dimensions 3 m x 3 m is placed 0.37 mm apart from a fixed plate. the plate requires a force of 2n to move at speed of 45 cm/s. evaluate the viscosity of the fluid in between the plates
Answers: 3
question
Engineering, 04.07.2019 19:20
A5 kg block of fe is dropped into a very large vat of water. the fe and water initial temperatures are 95 and 25 c, respectively. the fe final temperature is 25 c and the water can be treated as a thermal reservoir,. treated as a thermal reservoir take the water to be the system and determine the entropy generation. report vour answer in kj/k.
Answers: 1
You know the right answer?
Consider proportional-only control of the stirred-tank heater control system in fig. e11.13. the tem...
Questions
Questions on the website: 13722362