subject
Engineering, 18.11.2019 20:31 23stanforthb

Explain why the following paradigm does not give a secure authenticated encryption, i. e. an encryption scheme that satisfies both ind-cpa security and ciphertext integrity (adversary cannot make new ciphertext without knowing the key or asking the encryption oracle). the paradigm encryption algorithm first runs an enc algorithm on message m to obtain c, and then runs a tag algorithm on message m and obtains σ, the final ciphertext will be (c, σ).

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Asimple rankine cycle uses water as the working fluid. the water enters the turbine at 10 mpa and 480c while the condenser operates at 6 kpa. if the turbine has an isentropic efficiency of 80 percent while the pump has an isentropic efficiency of 70 percent determine the thermal efficiency
Answers: 1
question
Engineering, 04.07.2019 19:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 3
question
Engineering, 04.07.2019 19:10
Arigid tank contains 10 kg of air at 137 kpa (abs) and 21°c. more air is added to the tank until the pressure and temperature rise to 242 kpa (abs) and 32°c, respectively. determine the amount of air added to the tank. [r-0.287 kj/kg k]
Answers: 3
question
Engineering, 06.07.2019 03:30
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2
You know the right answer?
Explain why the following paradigm does not give a secure authenticated encryption, i. e. an encrypt...
Questions
question
History, 07.10.2019 13:50
question
Biology, 07.10.2019 13:50
question
Mathematics, 07.10.2019 13:50
Questions on the website: 13722361