Athree-phase wye-connected synchronous generator supplies a network through a transmission line. the network can absorb or deliver power while maintaining its terminal voltage constant. the four-pole, 60 hz generator data rating are 40 mva and 26 kv with a 0.85 p. u. reactance. the field current of the generator can be adjusted to regulate the excitation (induced) voltage from 0.75 to 1.5 times the rated voltage. the network voltage rating is 24 kv. the transmission line impedance and length are 0.07+j0.5 ω/mi and 8 mi. (a) calculate the generator induced voltage versus power factor, if the network voltage is at the rated value, and the bus absorbs the generator rated power. after this, plot the voltage regulation of the system versus the power factor. use the induced voltage and network voltage for plotting the voltage regulation. the leading power factor varies from 0.5 to 1. what power factor corresponds to 10% regulation? (b) plot the maximum power (power angle is 90°) versus induced voltage. determine the required induced voltage that allows the safe transfer of maximum power from the generator to the network (not to exceed the generator rating). assume that the network voltage is the same as in part (a). the excitation voltage is the variable.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
question
Engineering, 04.07.2019 19:10
Ahelical coil spring has a mean diameter of 50 mm, a wire diameter of 5.5 mm and is wound with a pitch of 10 mm. the spring steel has an ultimate strength of 1250 mpa. find the force needed to compress the spring solid and the wire stress in this condition. state whether the spring will return to its initial length.
Answers: 1
You know the right answer?
Athree-phase wye-connected synchronous generator supplies a network through a transmission line. the...
Questions
question
Mathematics, 21.10.2020 23:01
question
Mathematics, 21.10.2020 23:01
question
English, 21.10.2020 23:01
question
Mathematics, 21.10.2020 23:01
Questions on the website: 13722360