2. you are considering building a commercial pv solar power system to produce 50,000 kwh of electricity each year. the system will be composed of monocrystalline silicon panels with a cell efficiency of 18.7%. each panel will produce 200 w at full power and costs $175. the balance of system (bos) cost including installation of the panels and the necessary hardware and electrical components (wiring, inverter, and battery bank) and installation is $35,000. the system is estimated to have a capacity factor of 12% and a 25 year life expectancy. assume an operations and maintenance cost of $0.005/kwh. the annual discount rate is 5.5%. a. how many panels are required for the system? b. what is the capital cost (investment cost) of the system ($)? c. what is the annual cost for the fixed capital of the system ($/y)? d. what is the levelized cost of electricity for the pv system ($/kwh)?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:10
Calculate the bore of a cylinder that has a stroke of 18 inches and an extension time of 6 seconds at a flow rate of 4 gal/min.
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
2. you are considering building a commercial pv solar power system to produce 50,000 kwh of electric...
Questions
question
Mathematics, 13.10.2019 11:00
question
Mathematics, 13.10.2019 11:00
question
Biology, 13.10.2019 11:00
question
Mathematics, 13.10.2019 11:00
question
Mathematics, 13.10.2019 11:00
Questions on the website: 13722367