subject
Engineering, 20.09.2019 20:20 Bloom247

The following shear stress-shear rate data were obtained on a 6 wt% solution of sodium cellulose sulfate polymer in water at 24.5 °c. shear rate (s) 0.23 shear stress (pa) shear rate (s) shear stress (pa) 5.5 5.8 52 0.29 7 7.2 57 0.36 8.5 9.1 63 0.46 11.5 11 69 0.58 13 14.5 74 0.72 15 18 80 0.91 17.5 23 85 15 20.5 29 92 1.45 24 36 100 108 1.8 27.5 46 2.3 31.5 58 113 20 2.9 36 72 3.6 41 91 130 4.6 46 log-log scale plot the viscosity-shear rate function on a a. b. is there a shear rate range in which the fluid appears to be newtonian? is there a range in which the viscosity follows a power law relation? if so determine the power law constants and state what type of non-newtonian fluid it is the polymer solution is to be used in a process at a shear rate of 5000 s. estimate the viscosity under these conditions from the available data. do you think that the estimated c. d. value is reliable?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 18:10
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2
question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
You know the right answer?
The following shear stress-shear rate data were obtained on a 6 wt% solution of sodium cellulose sul...
Questions
question
Mathematics, 24.03.2021 19:40
question
Mathematics, 24.03.2021 19:40
question
Mathematics, 24.03.2021 19:40
question
Mathematics, 24.03.2021 19:40
question
Chemistry, 24.03.2021 19:40
Questions on the website: 13722367