Asingle-phase, 50-kva, 2400/240-v, 60-hz distribution transformer has the following parameters: resistance of the 2400-v winding: r1 = 0.75 ω resistance of the 240-v winding: r2 = 0.0075 ω reactance of the 2400-v winding: x1 = 1.0 ω reactance of the 240-v winding: x2 = 0.01 ω (neglect the exciting admittance) the transformer is supplying a rated load of 50 kva at a rated secondary voltage of 240-v and 0.8 power factor lagging. if the transformer is used as a step-down transformer at the load end of a feeder whose impedance is 0.5 + .0 ω, find the voltage vs and the power factor at the sending end of the feeder.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
You know the right answer?
Asingle-phase, 50-kva, 2400/240-v, 60-hz distribution transformer has the following parameters: res...
Questions
question
Computers and Technology, 29.08.2020 04:01
Questions on the website: 13722361