Engineering, 14.09.2019 04:20 swelch2010
An engine operates an ideal, air standard otto cycle with a compression ratio of 8. heat transfer to the engine is from a high temperature reservoir at 1000oc, and heat transfer from the engine to the surroundings at 20oc and 100kpa. at the beginning of the isentropic compression process the pressure and the temperature of the working fluid are 110kpa and 50oc. at the end of the combustion process the temperature is 900oc. calculate: (a) pressure and temperature of the remaining 3 states of the otto cycle. (b) thermal efficiency of the cycle. (c) mean effective pressure. (d) the maximum thermal efficiency for a heat engine operating between the heat reservoirs indicates.
Answers: 3
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
Engineering, 04.07.2019 19:10
With increases in magnification, which of the following occur? a. the field of view decreases. b. the ambient illumination decreases. c. the larger parts can be measured. d. the eyepiece must be raised.
Answers: 1
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
Engineering, 05.07.2019 23:20
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
An engine operates an ideal, air standard otto cycle with a compression ratio of 8. heat transfer to...
Mathematics, 11.12.2020 05:30
Mathematics, 11.12.2020 05:30
Social Studies, 11.12.2020 05:30
Mathematics, 11.12.2020 05:30
English, 11.12.2020 05:40
Biology, 11.12.2020 05:40
Mathematics, 11.12.2020 05:40
Mathematics, 11.12.2020 05:40
Mathematics, 11.12.2020 05:40
Chemistry, 11.12.2020 05:40
Mathematics, 11.12.2020 05:40