subject
Engineering, 14.09.2019 03:20 pin193179

Aconverging-diverging nozzle is designed to produce a mach number of 2.5 with air. a) what operating pressure ratio (preceiver/ptotal) will cause this nozzle to operate at the first, second, and third critical points? b) if the inlet stagnation pressure is 150 psia, what receiver pressures that represent the operation at these three critical points?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
question
Engineering, 04.07.2019 18:20
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
You know the right answer?
Aconverging-diverging nozzle is designed to produce a mach number of 2.5 with air. a) what operating...
Questions
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
German, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Biology, 18.09.2020 15:01
question
History, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Physics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
English, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
question
History, 18.09.2020 15:01
question
Social Studies, 18.09.2020 15:01
question
Mathematics, 18.09.2020 15:01
Questions on the website: 13722360