subject
Engineering, 10.09.2019 04:20 habsofarah0

Acontrol system has the following open-loop transfer function: a) draw the bode magnitude and the phase plots for .in particular: - draw the asymptotes and indicate their slopes, then sketch the real curves.- clearly mark the cutoff frequencies. b) calculate the phase margin the crossover frequency () and indicate them on the bode plots. using , estimate the damping ratio for the closed-loop poles. c) calculate the gain margin gm, the frequency at -180 deg () and indicate them on the bode plots.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
If a particle moves along a path such that r : (3 sin t) m and ? : 2t rad, where t is in seconds. what is the particle's acceleration in m/s in 4 seconds? a)- 16.43 b)- 16.29 c)- 15.21 d)- 13.79
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
You know the right answer?
Acontrol system has the following open-loop transfer function: a) draw the bode magnitude and the ph...
Questions
question
Mathematics, 22.02.2021 09:10
question
Mathematics, 22.02.2021 09:10
question
Physics, 22.02.2021 09:10
question
SAT, 22.02.2021 09:10
question
Mathematics, 22.02.2021 09:10
Questions on the website: 13722362