subject
Engineering, 09.09.2019 23:20 nommies005

(si units) in a tensile test, the starting gage length = 100.0 mm and the cross-sectional area = 150 mm2. during testing, the following force and gage length data are collected: (1) 17,790 n at 100.2 mm, (2) 23,040 n at 103.5 mm, (3) 27,370 n at 110.5 mm, (4) 28,910 n at 122.0 mm, (5) 27,480 n at 130.0 mm, and (6) 20,460 n at 135.1 mm. the final data point (6) occurred immediately prior to failure. yielding occurred at a load of 19,390 n (0.2% offset value), and the maximum load (4) was 28,960 n. (a) plot the engineering stress strain curve. determine (b) yield strength, (c) modulus of elasticity, (d) tensile strength, and (e) percent elongation.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
You know the right answer?
(si units) in a tensile test, the starting gage length = 100.0 mm and the cross-sectional area = 150...
Questions
question
Mathematics, 17.06.2021 19:50
question
Biology, 17.06.2021 19:50
question
English, 17.06.2021 19:50
question
Mathematics, 17.06.2021 20:00
question
Biology, 17.06.2021 20:00
Questions on the website: 13722359