subject
Engineering, 05.09.2019 20:30 jaybeast40

The exhaust-gas temperature leaving a continuously operating furnace is 260 c, and a proposal is being considered to install a heat exchanger in the exhaust-gas stream to generate low-pressure steam at 105 c. the question to be investigated is whether it is economical to install such a heat exchanger, and, if so, to find its optimum size. the following data apply: flow of exhaust gas, 7.5 kg/s. specific heat of exhaust gas, 1.05 kj/(kg k). value of the heat in the form of steam, $1.50 per gigajoule. u value of heat exchanger based on gas-side area, 23 w/(m2 k). cost of the heat exchanger including installation based on gas-side area, $90 per square meter. interest rate, 8 percent. life of installation, 5 years. saturated liquid water enters heat exchanger at 105 c and leaves as saturated vapor. (a) develop the equation for the savings as a function of the area, expressed as a uniform annual amount.(b) what is the maximum permitted area if the exit-gas temperature is to be above 120 c in order to prevent condensation of water vapor from the exhaust gas? (c) use a seven-point fibonacci search and set up a table to simplify calculation of the optimum heat-transfer area.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 19:20
A5 kg block of fe is dropped into a very large vat of water. the fe and water initial temperatures are 95 and 25 c, respectively. the fe final temperature is 25 c and the water can be treated as a thermal reservoir,. treated as a thermal reservoir take the water to be the system and determine the entropy generation. report vour answer in kj/k.
Answers: 1
question
Engineering, 04.07.2019 19:20
Apreheater involves the use of condensing steam at 100°c on the inside of a bank of tubes to heat air that enters at 1 atm and 25°c. the air moves at 5 m/s in cross flow over the tubes. each tube is 1 m long and has an outside diameter of 10 mm. what is the minimum value of nl needed to achieve an outlet temperature of t 75 c? what is the corresponding pressure drop across the tube bank?
Answers: 3
question
Engineering, 06.07.2019 06:10
The elements influencing a materials service performance include which of the following (mark all that apply) a)- stress b)- corrosion c)- temperature d)- vibration e)- operating cycles
Answers: 2
You know the right answer?
The exhaust-gas temperature leaving a continuously operating furnace is 260 c, and a proposal is bei...