subject
Engineering, 02.09.2019 19:10 emmagossett2002

Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 50°c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, (b) thema the mass flow rate of the refrigerant, the heating load and the cop of the pump, and (c) (d) the theoretical minimum power input to the compressor for the same heating load.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 19:20
Air at a pressure of 1atm and a temperature of 40 c is in parallel flow over the top surface of a flat plate that is heated to a uniform temperature of 120 c. the plate has a length of 0.40m (in the flow direction) and a width of 0.15m. the reynolds number based on the plate length is 50, 000. what is the rate of heat transfer from the plate to the air? if the free stream velocity of the air is doubled and the pressure is increased to 10 atm what is the rate of heat transfer?
Answers: 2
question
Engineering, 06.07.2019 03:10
Oxygen at 300 kpa and 400 k is in a closed system with an initial volume of 0.1 m3. is now compressed in a polytropic process, with exponent of n 1.2, to a temperature of 500 k. calculate: a) the boundary work done during the compression, in kj b) the heat transfer during the compression, in kj
Answers: 3
You know the right answer?
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing h...
Questions
question
Mathematics, 01.12.2020 17:00
question
Chemistry, 01.12.2020 17:00
question
Chemistry, 01.12.2020 17:00
question
Mathematics, 01.12.2020 17:00
question
Health, 01.12.2020 17:00
Questions on the website: 13722359