subject
Engineering, 27.08.2019 20:20 mxhx

Design a tower intake to be placed in a reservoir in a warm climate. provide the minimum number of ports. the design conditions are: summer design flow rate = 38,000 m^3/d maximum reservoir elevation = 499.0 m minimum reservoir elevation = 480.7 m lake bottom elevation = 477.7 m bar rack bars: 1 cm diameter: 8 cm between bars specify the following: number and location of intake ports spacing of the ports depth of lowest port depth of top port dimensions of a port provide a sketch of the following: intake tower with elevations of ports, reservoir elevations, and lake bottom elevation

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 16:10
The force on a cutting tool are 2600n vertically downward and 2100 horizontal. determine the resultant force acting on the tool and the angle at which it acts.
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 18:20
Atank with constant volume contains 2.27 kg of a mixture of water phases (liquid-vapor). in the initial state the temperature and the quality are 127 °c and 0.6, respectively. the mixture is heated until the temperature of 160 oc is reached. illustrate the process in a t-v diagram. then, determine (1) the mass of the vapor in kg at the initial state, (2) the final pressure in kpa.
Answers: 3
question
Engineering, 04.07.2019 19:20
Liquid flows at steady state at a rate of 2 lb/'s through a pump, which operates to raise the elevation of the liquid 100 ft from control volume inlet to exit. the liquid specific enthalpy at the inlet is 40.09 btu/lb and at the exit is 40.94 btub. the pump requires 3 btu/s of power to operate. if kinetic energy effects are negligible and gravitational acceleration is 32.174 tt/s, the heat transfer rate associated with this steady state process is most closely 1)-2,02 btu/s from the liquid to the surroundings 2)-3.98 btu/s from the surroundings to the liquid. 3)-4.96 btu/s from the surroundings to the liquid. 4)-1.04 btu/s from the liquid to the surroundings.
Answers: 2
You know the right answer?
Design a tower intake to be placed in a reservoir in a warm climate. provide the minimum number of p...
Questions
question
Arts, 03.05.2021 16:10
question
Mathematics, 03.05.2021 16:10
question
Mathematics, 03.05.2021 16:10
question
Mathematics, 03.05.2021 16:10
Questions on the website: 13722367