subject
Engineering, 21.08.2019 16:20 marie2061

Aheat pump is used to warm a building in the winter. this system implements an ideal vapor-compression cycle with r-134a as the working fluid. the cycle operates between 160 kpa and 700 kpa, with a mass flow rate of 0.02 kg/s. determine: (a) the heating load that can be met (b) the power input required for this kw (c) the coefficient of (d) the warmest outside temperature at which this particular cycle is unable to operate ∘c

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Steam enters a converging nozzle at 3.0 mpa and 500°c with a at 1.8 mpa. for a nozzle exit area of 32 cm2, determine the exit velocity, mass flow rate, and exit mach number if the nozzle: negligible velocity, and it exits (a) is isentropic (b) has an efficiency of 94 percent
Answers: 2
question
Engineering, 04.07.2019 19:20
In the winter, in order to keep the classroom steadily at 68 f before 10 pm, heating with an average rate of 42,000 btu/hr is provided. assume the outdoor temperature maintains at 32°f, determine the electrical power (kw) required to (a) operate a reversible heat pump (b) operate a real heat pump with a cop (7) of 4.5 and (c) operate an electrical-resistance heater.
Answers: 3
question
Engineering, 04.07.2019 19:20
Acircular pipe of 30mm outside diameter is placed in an airstream at 30 c and latm pressure. the air moves in cross flow over the pipe at 20 m/s, while the outer surface of the pipe is maintained at 110 c. what is the drag force exerted on the pipe per unit length? what is the rate of heat transfer from the pipe per unit length?
Answers: 1
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
You know the right answer?
Aheat pump is used to warm a building in the winter. this system implements an ideal vapor-compressi...
Questions
question
Mathematics, 05.01.2021 22:20
question
English, 05.01.2021 22:20
question
Spanish, 05.01.2021 22:20
question
History, 05.01.2021 22:20
Questions on the website: 13722360