Engineering, 09.08.2019 03:20 chony83

An air conditioner with refrigerant-134a (r-134a) as the working fluid is used to keep a room at 26°c by rejecting the waste heat to the outside air at 34°c. the room is gaining heat through the walls and the windows at a rate of 250 kj/min while the heat generated by the computer, tv, and lights amounts to 900 w. an unknown amount of heat is also generated by the people in the room. the condenser and evaporator pressures are 1200 and 500 kpa, respectively. the refrigerant is saturated liquid at the condenser exit and saturated vapor at the compressor inlet. if the refrigerant enters the compressor at a rate of 100 l/min and the isentropic efficiency of the compressor is 75 percent, determine (a) the temperature of the refrigerant at the compressor exit, (b) the rate of heat generation by the people in the room, (c) the cop of the air conditioner, and (d) the minimum volume flow rate of the refrigerant at the compressor inlet for the same compressor inlet and exit conditions

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
You know the right answer?
An air conditioner with refrigerant-134a (r-134a) as the working fluid is used to keep a room at 26°...
Questions
question
Mathematics, 03.03.2021 21:00
question
Mathematics, 03.03.2021 21:00
question
Mathematics, 03.03.2021 21:00
question
Mathematics, 03.03.2021 21:00
question
Mathematics, 03.03.2021 21:00
Questions on the website: 13722363