subject
Engineering, 01.08.2019 00:30 devnnn44

What do you believe is the most important aspect or criteria for developing and validating an effective response plan? why do you see this as the most important aspect? is there any literature to support your response? provide the reference or citationthat supports your position. the criteria for developing and validating an effective response plan includes seven (6) steps as outlined below:
1. acceptability - the plan must anticipate scenarios which are consistent with applicable laws.
2. adequacy – the plan must comply with all applicable planning guidance from fema, homeland security, etc.
3. completeness – the plan must incorporate major actions, objectives and tasks.
4. consistency and standardization of products – the plan must be consistent with all other related documents.
5. feasibility – the plan must include feasible tasks to be accomplished with the resources that are available.
6. flexibility – the plan must be flexible enough to include accommodate all hazards and contingency plan.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Apiston-cylinder device contains 0.1 m3 of liquid water and 0.9 m3 of water vapor in equilibrium at 800 kpa. heat is transferred at constant pressure until the temperature of water reaches 350 Β°c. determine (a) the quality of water at the initial state (b) the work associated with this process, (c) the heat associated with this process.
Answers: 2
question
Engineering, 04.07.2019 19:10
How to increase the thermal officiency of an ideal simple rankino cycle? among these methods, which one is the best and why?
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25Β°c and -5Β°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
question
Engineering, 04.07.2019 19:20
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90Β° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
You know the right answer?
What do you believe is the most important aspect or criteria for developing and validating an effect...
Questions
Questions on the website: 13722363