subject
Engineering, 11.07.2019 01:30 ladybugperez05

A30-kg iron block and a 40-kg copper block, both initially at 80°c, are dropped into a large lake at 15°c. ther- mal equilibrium is established after a while as a result of heat transfer between the blocks and the lake water. determine the total entropy change for this process.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 19:10
Estimate the change in specific internal energy au and specific enthalpy h from inlet to outlet for ethylene glycol (a liquid) flowing through each of the following devices: (a) a heat exchanger where the glycol temperature increases from 20 °c to 80 °c; (b) a pump operating at about 25 °c and increasing the glycol pressure from 100 kpa to 8 mpa.
Answers: 2
question
Engineering, 04.07.2019 19:20
In the winter, in order to keep the classroom steadily at 68 f before 10 pm, heating with an average rate of 42,000 btu/hr is provided. assume the outdoor temperature maintains at 32°f, determine the electrical power (kw) required to (a) operate a reversible heat pump (b) operate a real heat pump with a cop (7) of 4.5 and (c) operate an electrical-resistance heater.
Answers: 3
question
Engineering, 06.07.2019 03:30
The catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40°c and an evaporating temperature of -4°c shows a refrigeration capacity of 115 kw. at this operating point, the motor (its efficiency is 90 percent) draws 34.5 kw. the bore of the cylinders is 87 mm and the piston stroke is 70 mm. the performance data are based on 8°c of sub-cooling of the liquid leaving the condenser. compute (a) the actual volumetric efficiency and (b) the compression efficiency.
Answers: 2
question
Engineering, 06.07.2019 04:10
Aheat pump using refrigerant-134a heats a house by using underground water at 8°c as the heat source. the house is losing heat at a rate of 60,000 kj/h. the refrigerant enters the compressor at 280 kpa and 0°c, and it leaves at 1 mpa and 60°c. the refrigerant exits the condenser at 30°c. determine: (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump
Answers: 2
You know the right answer?
A30-kg iron block and a 40-kg copper block, both initially at 80°c, are dropped into a large lake at...
Questions
question
Health, 08.04.2021 17:20
question
Mathematics, 08.04.2021 17:20
question
Mathematics, 08.04.2021 17:20
question
Mathematics, 08.04.2021 17:20
question
Mathematics, 08.04.2021 17:20
question
Mathematics, 08.04.2021 17:20
Questions on the website: 13722367